header siamhitech
 

หมวดสินค้า

Digital Timer ยี่ห้อ Omron รุ่น H5CZ-L8 (new)

Digital Timer ยี่ห้อ Omron รุ่น H5CZ-L8 (new)
รหัสสินค้า: 005063
สถานะสินค้า: มีสินค้า
ราคา: 1,700.00 บาท
จำนวน:  
   - หรือ -   

Digital Timer ยี่ห้อ Omron

รุ่น H5CZ-L8

(new)

Item Feature
Number of Digits
4-digit
Release Voltage
10% of the supply voltage
Minimum Signal Input Time (sec)
1m/20m (collectively switching)
Power Supply Voltage (V)
AC100 to 240
Weight (g)
About 105 (body only)
Power Consumption
About 6.2VA
Character Height (mm)
(LCD) timing value: 10 setting: 6
Noise Immunity
Between power terminals: +/- 1.5kV between input terminals: square wave noise by +/- 600V noise simulator (pulse width 100ns/1micros, rising 1ns)
Storage Temperature (DegreeC)
-25 - +70 deg C (icing or no condensation)
Sensor Waiting Time
(During sensor waiting time and no input is accepted control output OFF) 250ms or less
Display Mode
Adding (UP) display and subtraction (DOWN) display (switching)
Mounting Method
Flush mounting, surface mounting (shared)
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Insulation Resistance (Mohm)
(Non-current-carrying metal parts between the exposed conductive portion terminal, non-continuous contacts between) 100 or more (by DC500V mega)
Withstand Voltage
Power and AC2000V 50/60Hz 1min control output, input circuit between: input circuit between the AC2000V 50/60Hz 1min power: non-current-carrying metal parts between the current-carrying metal parts AC2000V 50/60Hz 1min non- Continuous contact between: AC1000V 50/60Hz 1min
Power Reset
(Except A-3, b-1, F, the ton-1, toff-1 mode) 0.5s: minimum power-supply cut-off time
Operating Time Variation
(In the case of start signal) 0.005% +/- 0.03s or less (at power supply start) +/- 0.01% +/- 0.05s or less (and are based on the set value) +/-
Impulse Voltage(V)
Non-current-carrying metal parts between the exposed and 3.0k conductive part terminal:: 4.5k between power supply terminals
Voltage Influence
(In the case of start signal) 0.005% +/- 0.03s or less (at power supply start) +/- 0.01% +/- 0.05s or less (and are based on the set value) +/-
Vibration Resistance
10 - 55Hz single amplitude 0.75mm 3 directions of the 2h
Power Failure Memory
More than 10 years: retention of data (100 000 times or more the number of rewriting times) EEP-ROM
Ambient Humidity
25 to 85%
Electrostatic Yield Strength
8kV (malfunction), 15kV (destruction)
One shot time
0.01 to 99.99s
Color
Front panel: Light gray (5Y7 / 1)
Input Signal
Signal, reset
Terminal Structure
Socket type (8-pin)
Set Error
(In the case of start signal) 0.005% +/- 0.03s or less (at power supply start) +/- 0.01% +/- 0.05s or less (and are based on the set value) +/-
Operating Mode
A: Signal ON delay (I) A-1: Signal ON delay (II) A-2: Power ON Delay (I) A-3: Power ON-delay (II) b: flicker (I) b-1: flicker (II) d: Signal OFF-delay E: interval F: cumulative Z: ON / OFF duty vari
Time Base Range
9.999s (0.001s -), 99.99s (0.01s -), 999.9s (0.1s -), 9999s (1s -), 99min59s (1s -), 999.9min (0.1min -), 9999min (1min -), 99h59min (1min -), 999.9h (0.1h -), 9999h (1h -)
Control Output
(P level, reference value) DC5V 10mA: (cosphi = 1) minimum applicable load AC250/DC30V 5A resistive load
Allowable Voltage Range
85-110% of rated supply voltage
Effect of Temperature
(In the case of start signal) 0.005% +/- 0.03s or less (at power supply start) +/- 0.01% +/- 0.05s or less (and are based on the set value) +/-
Protection Structure
IP66, UL508 Type 4X IEC standard (indoor), but only the panel surface (waterproof packing type Y92S-29 is used)
Reset Method
Power reset (by the output mode), external reset, manual reset, automatic reset (by the output mode)
Operating Ambient Temperature (deg C)
-10 - +55 deg C (when mounted side by side: -10 - +50 deg C) (icing or no condensation)
Lifespan
(AC250V 5A resistive load, 1800 times / h, ambient temperature conditions more than 100,000 times: electrical and mechanical:: (23 deg C 1800 times / h time no load, a switching frequency, ambient temperature conditions) 10 million times or more : 23 deg C)
Output Type
Contact output (time limit 1c)
Input Method
100kohm impedance: when opened 3V following: short-circuit residual voltage (about 12mA current flow when 0ohm) 1kohm following: No-voltage input impedance short-circuit
Vibration Resistance (malfunction)
10 - 55Hz single amplitude 0.35mm 3 directions of the 10min
Impact Resistance (Malfunction)
3 times each in 100m / s 2 3 axis each direction
Impact Resistance
3 times each in 300m / s 2 3 axis each direction
Siamhitech © 2024 | Doodeedesign.com รับทำเว็บไซต์